DePuy Synthes 1.7-mm cable
1.7 Mm Cable, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/1.7-mm cable/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
1.7-mm cable - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes depuy cable tensioner
Depuy Cable Tensioner, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/depuy cable tensioner/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
depuy cable tensioner - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes cerclage passer device
Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. <t>Cerclage</t> wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.
Cerclage Passer Device, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cerclage passer device/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
cerclage passer device - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes 1.7-mm cobalt-chrome cable
Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. <t>Cerclage</t> wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.
1.7 Mm Cobalt Chrome Cable, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/1.7-mm cobalt-chrome cable/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
1.7-mm cobalt-chrome cable - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes trauma cable
Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. <t>Cerclage</t> wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.
Trauma Cable, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/trauma cable/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
trauma cable - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes gripping cables
Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. <t>Cerclage</t> wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.
Gripping Cables, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/gripping cables/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
gripping cables - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes sofwire cable system
Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. <t>Cerclage</t> wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.
Sofwire Cable System, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/sofwire cable system/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
sofwire cable system - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes cable system
Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. <t>Cerclage</t> wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.
Cable System, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cable system/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
cable system - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes titanium cable
Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. <t>Cerclage</t> wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.
Titanium Cable, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/titanium cable/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
titanium cable - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes peristernal cable-tie devices
Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. <t>Cerclage</t> wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.
Peristernal Cable Tie Devices, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/peristernal cable-tie devices/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
peristernal cable-tie devices - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes stainless-steel cerclage cables with crimp and diameter
Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. <t>Cerclage</t> wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.
Stainless Steel Cerclage Cables With Crimp And Diameter, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/stainless-steel cerclage cables with crimp and diameter/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
stainless-steel cerclage cables with crimp and diameter - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes 1.8-mm diameter stainless steel cables
Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. <t>Cerclage</t> wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.
1.8 Mm Diameter Stainless Steel Cables, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/1.8-mm diameter stainless steel cables/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
1.8-mm diameter stainless steel cables - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

Image Search Results


Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. Cerclage wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.

Journal: Chinese Journal of Traumatology

Article Title: Role of percutaneous cerclage wire in the management of subtrochanteric fractures treated with intramedullary nails

doi: 10.1016/j.cjtee.2018.01.001

Figure Lengend Snippet: Pre-operative radiograph (A) in a 50 year-old-lady following fall from height. Cerclage wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ). It consists of two dividable forceps which is passed ventral and dorsal to the fracture, and clamped outside. SS wire is passed through the cannulation inside the forceps (B). Reduction achieved and cerclage loop was tightened around the fracture (C). Anatomic reduction facilitated accurate localization of entry portal (D, E) for intramedullary (IM) nailing. Head-neck screw was inserted through the same incision (F). Post-operative antero-posterior (AP) and lateral radiographs (G) showing stable anatomical reduction.

Article Snippet: Cerclage wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ).

Techniques:

Baseline demographic characteristics of study patients.

Journal: Chinese Journal of Traumatology

Article Title: Role of percutaneous cerclage wire in the management of subtrochanteric fractures treated with intramedullary nails

doi: 10.1016/j.cjtee.2018.01.001

Figure Lengend Snippet: Baseline demographic characteristics of study patients.

Article Snippet: Cerclage wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ).

Techniques:

Pre-operative radiographs in a 26-year-old male following road traffic accident (A). Percutaneous cerclage wire assisted reduction and IM nailing was performed (B). AP and lateral radiographs (C, D) one and half years post-operatively depicting satisfactory fracture reduction, and alignment with complete bony healing.

Journal: Chinese Journal of Traumatology

Article Title: Role of percutaneous cerclage wire in the management of subtrochanteric fractures treated with intramedullary nails

doi: 10.1016/j.cjtee.2018.01.001

Figure Lengend Snippet: Pre-operative radiographs in a 26-year-old male following road traffic accident (A). Percutaneous cerclage wire assisted reduction and IM nailing was performed (B). AP and lateral radiographs (C, D) one and half years post-operatively depicting satisfactory fracture reduction, and alignment with complete bony healing.

Article Snippet: Cerclage wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ).

Techniques:

32-year-old man sustained subtrochanteric femur fracture following fall from height (A). Post-operative radiographs (B, C) after cephalomedullary nailing with additional cerclage wire showing anatomic reduction and stable construct. Two years Post-operative radiographs revealing uneventful healing of fracture in satisfactory alignment (D, E). Patient regained excellent function and resumed pre-injury activity level (F, G).

Journal: Chinese Journal of Traumatology

Article Title: Role of percutaneous cerclage wire in the management of subtrochanteric fractures treated with intramedullary nails

doi: 10.1016/j.cjtee.2018.01.001

Figure Lengend Snippet: 32-year-old man sustained subtrochanteric femur fracture following fall from height (A). Post-operative radiographs (B, C) after cephalomedullary nailing with additional cerclage wire showing anatomic reduction and stable construct. Two years Post-operative radiographs revealing uneventful healing of fracture in satisfactory alignment (D, E). Patient regained excellent function and resumed pre-injury activity level (F, G).

Article Snippet: Cerclage wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ).

Techniques: Construct, Activity Assay

Summarized depiction of perioperative data and results.

Journal: Chinese Journal of Traumatology

Article Title: Role of percutaneous cerclage wire in the management of subtrochanteric fractures treated with intramedullary nails

doi: 10.1016/j.cjtee.2018.01.001

Figure Lengend Snippet: Summarized depiction of perioperative data and results.

Article Snippet: Cerclage wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ).

Techniques:

Brief overview and comparison with other published studies.

Journal: Chinese Journal of Traumatology

Article Title: Role of percutaneous cerclage wire in the management of subtrochanteric fractures treated with intramedullary nails

doi: 10.1016/j.cjtee.2018.01.001

Figure Lengend Snippet: Brief overview and comparison with other published studies.

Article Snippet: Cerclage wire assisted reduction was performed through a small lateral incision by percutaneous cerclage passer device (DepuySynthes ® ).

Techniques: Comparison, Infection, Activity Assay